Go to content
Skip menu
Skip menu
Protecting Cable Ducts: From Copper Theft to Critical Infrastructure Security
GPS Standard - Anti-intrusion Perimeter Systems
Published by Communication Office in Business · Thursday 06 Aug 2026 · Read time 10 minutes
Tags: cable, ducts, copper, theft, infrastructure, security, power, grids, telecommunications, railway, networks, industrial, infrastructure, security, risks, critical, infrastructure
When discussing the security of cable ducts, the first risk that comes to mind is almost always copper theft. It is a concrete and growing problem that, in recent years, has affected power grids, telecommunications, railway networks, and industrial infrastructures across various countries.
 
However, viewing cable duct protection solely as a matter of theft prevention means barely scratching the surface of the problem. In many modern infrastructures, the value of the cable itself is far lower than the value of the service that cable enables.
 
A cable duct can carry power, telecommunications, data, railway signaling, or vital connections for the operation of an industrial plant. When a stretch is damaged, cut, or intentionally compromised, the consequences can be far more significant than the mere cost of replacing the cable. For this reason, perimeter protection for linear infrastructure must be treated as an essential component of physical security and operational continuity, not simply as an intrusion detection system designed to protect a physical asset.

 
Copper Theft Is Only Part of the Risk
 
The phenomenon of copper theft clearly demonstrates how much the operating context has changed for security managers. A recent article in the Financial Times highlighted how the surging value of copper is fueling a new wave of thefts impacting telecom networks, railway systems, and energy grids worldwide. The issue is therefore not just about the stolen material, but also the severe operational fallout resulting from service disruptions.
 
In the UK, for example, cable theft has had a major impact on telecommunications networks. Openreach estimated billions of pounds in damages over roughly a decade, while thousands of users experienced connectivity outages. In the railway sector, cable theft leads to delays, cancellations, and disruptions whose costs vastly exceed the value of the copper recovered by criminals.
 
This brings us to a fundamental concept in perimeter security: the asset to be protected is not necessarily the one we see. The cable represents the physical infrastructure, but the true asset is the service flowing through it. A data network, a railway communication system, or a critical infrastructure connection can have an operational value enormously higher than the physical material making it up.
 
Perimeter intrusion detection must therefore start from an understanding of this value and the consequences an infrastructure failure would entail.

 
A Cable Duct Can Be Exposed to Multiple Types of Threats
 
Theft represents only one of several scenarios that must be evaluated during a risk assessment. A cable duct can be accidentally damaged during excavation work, targeted by vandalism or sabotage, or intentionally accessed by individuals seeking to disrupt a service or gain physical entry to the infrastructure.
 
When cables carry sensitive information, the problem takes on an even greater dimension. Unauthorized physical access to the network can pose a major risk even if cable theft isn't the primary goal. In certain scenarios, infrastructure tampering or physical wiretapping attempts can become part of a broader, more sophisticated attack.
 
For this reason, designing perimeter security for a cable duct requires a thorough threat assessment from the outset. Before discussing PIDS, cameras, fiber optics, or other detection technologies, one must understand what infrastructure is being protected, where it is located, how accessible it is, what realistic threats exist, and what the impact of an outage would be.
 
It is a simple yet crucial principle: technology should be the outcome of a risk assessment, not the starting point of the project.

 
Perimeter Protection for Linear Infrastructure Presents Unique Challenges
 
Securing the perimeter of a building can be designed around a relatively compact, easily definable area. However, when protecting a cable duct that stretches over several kilometers, the challenges change entirely. The infrastructure may cross industrial zones, farmland, urban areas, roads, railways, and remote terrains—each with vastly different environmental conditions and accessibility levels along the route.
 
In this scenario, merely knowing that an event has occurred is not enough. For effective perimeter intrusion management, it is essential to know where it happened and, ideally, to have enough information to understand its nature. A generic alarm signaling a problem along a multi-kilometer stretch is of limited operational use, especially when the response team has to cover vast distances to reach the point of interest.
 
Therefore, in linear infrastructure protection, pinpointing location is often just as vital as detecting the intrusion itself. A PIDS (Perimeter Intrusion Detection System) must be evaluated not only on its ability to trigger an alarm, but also on the quality of information it provides to operators.
 
An effective perimeter security system should help answer very practical questions: Where is the incident occurring? How credible is the alarm? What type of disturbance was detected? And how quickly can the situation be verified and managed?

 
PIDS and Fiber Optics in Cable Duct Protection
 
Distributed fiber optic sensing technologies represent one of the most effective solutions available for securing linear infrastructure. In this application, the fiber optic cable acts as a continuous sensing element along the protected path, detecting mechanical vibrations associated with activities like digging, tampering, or physical damage attempts.
 
The primary advantage of a distributed approach is the ability to monitor vast distances while maintaining precise location accuracy. This is particularly advantageous when the perimeter isn't defined by a physical fence, but by an infrastructure stretching over many kilometers.
 
Even here, however, focusing solely on technology isn't enough. A PIDS shouldn't be selected simply because it offers a specific technical feature or appears easy to install. The choice should depend on the risk assessment, environmental conditions, stretch length, required precision, and above all, the operational procedures that will be triggered once an alarm is raised.
 
A perimeter intrusion system only delivers true value when the data it generates can be swiftly translated into an actionable decision. If an alarm cannot be verified or lacks an adequate response protocol, even the most sophisticated technology risks being ineffective.

 
GPS Standard’s Experience with MILES
 
This philosophy drives GPS Standard’s approach to linear infrastructure protection. Over the years, numerous projects have been developed where perimeter security for cable ducts, pipelines, and expansive sites required much more than traditional detection methods.
 
GPS Standard developed MILES specifically for these applications. The system utilizes fiber optics and interferometric technology to detect mechanical disturbances along the protected infrastructure. For cable ducts, this allows operators to monitor the entire route and pinpoint the exact area where activity consistent with digging, tampering, or damage is detected.
 
According to GPS Standard's technical documentation, MILES can be configured to protect stretches of up to 25 kilometers and locate events with an accuracy down to a few meters, depending on configuration and application. Furthermore, using fiber optics as the sensing element requires no electrical power along the perimeter and is completely immune to electromagnetic interference—a common obstacle for other technologies.
 
These features make MILES a particularly compelling technology for perimeter security and intrusion protection in linear infrastructures. However, technology should never be viewed in isolation from its context. The same solution can yield dramatically different effectiveness depending on the environment, the type of infrastructure, and the security protocols implemented by the client.

 
Risk Assessment Before Technology
 
This is perhaps the most critical point when it comes to cable duct protection. Before selecting a PIDS or any other detection technology, one must clarify what risk is being mitigated.
 
The question shouldn't simply be "Which system should we install?" but rather
 
     
  • What needs to be protected?
  •  
  • What are the most realistic threats?
  •  
  • What are the infrastructure's vulnerabilities?
  •  
  • What would be the impact of an incident?
 
Additionally, one must evaluate the time gap between event onset and detection, as well as the time required to dispatch a response.
 
A cable duct running through a busy industrial zone presents very different challenges than one crossing an isolated rural area. Similarly, the service being carried changes the evaluation entirely: a secondary connection and a line supporting a vital utility cannot be treated the same way.
 
Physical security is not merely a collection of devices. It is a process that starts with identifying assets and threats, and moves through technology selection, system integration, and response protocol definition.

 
From Physical Security to Infrastructure Resilience
 
This topic becomes even more critical when the cable duct belongs to critical infrastructure. Europe’s increasing focus on infrastructure resilience is driving organizations to intertwine physical security, cybersecurity, and operational continuity more closely than ever.
 
The CER Directive (2022/2557) introduced a European framework dedicated to the resilience of critical entities, mandating risk assessments and appropriate measures to prevent incidents and protect infrastructure. Concurrently, NIS2 has raised the bar for resilience and risk management regarding network and information system security.
 
For linear infrastructure, this evolution is particularly meaningful. Physical damage can trigger a digital service outage, while a cyber incident affecting a digital service can have tangible physical operational consequences.
 
Perimeter security must therefore be viewed within a broader framework of overall resilience. PIDS, video surveillance, access control, communications systems, and response protocols must work in unison whenever the risk level demands it.

 
Protecting the Cable Duct Means Protecting What Flows Inside
 
In the end, the key question isn't how much the copper inside the cable is worth.
 
The key question is: How much is the service enabled by that cable worth?
 
This is the perspective that should guide the design of perimeter security for linear infrastructure. Copper theft may be the visible, immediate event, but the true impact manifests as lost connectivity, service outages, operational downtime, safety hazards, and financial or reputational damage.
 
Securing a cable duct should never be treated as merely mounting a sensor along a pathway. It demands a thorough risk assessment, sound physical security design, selection of the right technology, and seamless integration between PIDS, video surveillance, and alarm management systems.
 
The expertise developed by GPS Standard with MILES is built on this very approach: engineering technology to solve real perimeter security challenges and applying it to match the unique demands of the infrastructure.
 
Because the true goal of security isn't just detecting an intrusion.
 
It's understanding what is happening, where it is happening, and how quickly you can respond to prevent an incident from becoming a service outage.

 
Protecting the cable duct means protecting everything that relies on it.

 
Sources & Further Reading
 


0 / 5
There are no reviews yet.
Rate:5
Number of rates:0 
Percentage of ratings:(0%)
Rate:4
Number of rates:0 
Percentage of ratings:(0%)
Rate:3
Number of rates:0 
Percentage of ratings:(0%)
Rate:2
Number of rates:0 
Percentage of ratings:(0%)
Rate:1
Number of rates:0 
Percentage of ratings:(0%)
Your opinion is important to us and helps us improve our service.
Write a Review
Back to content
Application icon
GPS Standard - Anti-intrusion Perimeter Systems Install this application on your home screen for a better experience
Tap Installation button on iOS then "Add to your screen"